disable drop-untag
Syntax: disable drop-untag <port range>
Description: Disables dropping of untagged frames.
Arguments:
<port range>: which ports to change, can be a single port (e.g. “1”) or a range of ports (e.g. “5-7”), range
from 1-8.
Possible values: <range>: 1 to 8
Example:
SS2GD8I(vlan)# disable drop-untag 5-8
disable sym-vlan
Syntax: disable sym-vlan <port range>
Description: Disables dropping of frames from non-member port(s).
Arguments:
<port range>: which ports to change, can be a single port (e.g. “1”) or a range of ports (e.g. “5-7”), range
from 1-8.
Example:
SS2GD8I(vlan)# disable sym-vlan 5-8
enable drop-untag
Syntax: enable drop-untag <port range>
Description: Drops untagged frames.
Arguments:
<port range>: which ports to change, can be a single port (e.g. “1”) or a range of ports (e.g. “5-7”), range
from 1-8.
Example:
SS2GD8I(vlan)# enable drop-untag 5-8
enable sym-vlan
Syntax: enable sym-vlan <range>
Description: Enabled dropping of frames from non-member port(s).
Arguments:
<port range>: which ports to change, can be a single port (e.g. “1”) or a range of ports (e.g. “5-7”), range
from 1-8.
Example:
SS2GD8I(vlan)# enable sym-vlan 5-8